SENSITIVITY OF ENERGY PERFORMANCE TO THE SELECTION OF PCM MELTING TEMPERATURE FOR THE BUILDING LOCATED IN CFB CLIMATE ZONE
Loading...
Date
Authors
Bozzhigitov, Abylaikhan
Memon, Shazim Ali
Adilkhanova, Indira
Journal Title
Journal ISSN
Volume Title
Publisher
Energy Reports
Abstract
In the present study, optimization of PCM layer thickness and melting temperature to increase the
energy-saving potential of the office building located in eight cities in the Cfb climate zone was
conducted using the Fanger model. The sensitivity of the energy savings to the selection of PCM melting
temperature was quantitatively analyzed using a novel indicator of average savings drop. Additionally,
the investigation of the effect of real PCMs on the energy performance of the building located in Cfb
climate as well as the economic and environmental analyses were accomplished. The results showed
that the PCM layer with a thickness of 2 cm reached the highest values of energy savings per unit
thickness. The optimization of the PCM melting temperature revealed that PCM 22–25 were optimum
for the whole Cfb climate zone and resulted in energy consumption reduction values of up to 37.6%. The
sensitivity analysis showed that the steadiness of the outdoor climate conditions affects the sensitivity
of the energy savings to the selection of PCM melting temperature. The analysis of real PCMs revealed
that PCM 25-r demonstrated more efficient performance in all cities. Overall, it was concluded that
the integration of PCM can be considered an economically and environmentally feasible solution.
Description
Citation
Bozzhigitov, A., Memon, S. A., & Adilkhanova, I. (2022). Sensitivity of energy performance to the selection of PCM melting temperature for the building located in Cfb climate zone. Energy Reports, 8, 6301–6320. https://doi.org/10.1016/j.egyr.2022.04.059
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwised noted, this item's license is described as Attribution-NonCommercial-ShareAlike 3.0 United States