COPPER-COATED SPACER FOR TOTAL FEMORAL REPLACEMENT IN RECURRENT PERIPROSTHETIC JOINT INFECTION: A CASE REPORT
| dc.contributor.author | Belokobylov, A. | |
| dc.contributor.author | Batpenov, N.D. | |
| dc.contributor.author | Balgazarov, S.S. | |
| dc.contributor.author | Serikbayev, V.D. | |
| dc.contributor.author | Krikliviy, A.A. | |
| dc.contributor.author | Plotnikov, S.V. | |
| dc.contributor.author | Turlybekuly, A. | |
| dc.contributor.author | Rimashevskiy, D.V. | |
| dc.date.accessioned | 2021-12-27T11:40:06Z | |
| dc.date.available | 2021-12-27T11:40:06Z | |
| dc.date.issued | 2021 | |
| dc.description.abstract | There are few cases of entire femur modular replacement with hip and knee joints in patients with periprosthetic joint infection (PJI) in literature. They report encouraging results in patients of elderly and senile age. We present case of a copper-coated femoral spacer implantation to 50-year-old patient with multiple PJI episodes and osteomyelitis of the entire femur. | en_US |
| dc.identifier.citation | Белокобылов, А. А., Batpenov, N. D., Balgazarov, S. S., Serikbayev, V. D., Krikliviy, A. A., Plotnikov, S. V., Turlybekuly, A., & Rimashevskiy, D. V. (2021). Copper-Coated Spacer for Total Femoral Replacement in Recurrent Periprosthetic Joint Infection: A Case Report. Traumatology and Orthopedics of Russia, 27(1), 175–182. https://doi.org/10.21823/2311-2905-2021-27-1-175-182 | en_US |
| dc.identifier.uri | http://nur.nu.edu.kz/handle/123456789/5969 | |
| dc.language.iso | en | en_US |
| dc.publisher | A Case Report | en_US |
| dc.rights | Attribution-NonCommercial-ShareAlike 3.0 United States | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/3.0/us/ | * |
| dc.subject | Type of access: Open Access | en_US |
| dc.subject | total hip replacement | en_US |
| dc.subject | periprosthetic joint infection | en_US |
| dc.subject | periprosthetic fracture | en_US |
| dc.subject | articulating spacer | en_US |
| dc.subject | copper coating | en_US |
| dc.title | COPPER-COATED SPACER FOR TOTAL FEMORAL REPLACEMENT IN RECURRENT PERIPROSTHETIC JOINT INFECTION: A CASE REPORT | en_US |
| dc.type | Article | en_US |
| workflow.import.source | science |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Copper-Coated Spacer for Total Femoral.pdf
- Size:
- 1.08 MB
- Format:
- Adobe Portable Document Format
- Description:
- Article