COPPER-COATED SPACER FOR TOTAL FEMORAL REPLACEMENT IN RECURRENT PERIPROSTHETIC JOINT INFECTION: A CASE REPORT
Loading...
Date
Authors
Belokobylov, A.
Batpenov, N.D.
Balgazarov, S.S.
Serikbayev, V.D.
Krikliviy, A.A.
Plotnikov, S.V.
Turlybekuly, A.
Rimashevskiy, D.V.
Journal Title
Journal ISSN
Volume Title
Publisher
A Case Report
Abstract
There are few cases of entire femur modular replacement with hip and knee joints in patients with periprosthetic joint infection (PJI) in literature. They report encouraging results in patients of elderly and senile age. We present case of a copper-coated femoral spacer implantation to 50-year-old patient with multiple PJI episodes and osteomyelitis of the entire femur.
Description
Citation
Белокобылов, А. А., Batpenov, N. D., Balgazarov, S. S., Serikbayev, V. D., Krikliviy, A. A., Plotnikov, S. V., Turlybekuly, A., & Rimashevskiy, D. V. (2021). Copper-Coated Spacer for Total Femoral Replacement in Recurrent Periprosthetic Joint Infection: A Case Report. Traumatology and Orthopedics of Russia, 27(1), 175–182. https://doi.org/10.21823/2311-2905-2021-27-1-175-182