ANALYTICAL CURRENT THD EVALUATION FOR THREE-PHASE VOLTAGE SOURCE INVERTERS
Loading...
Date
Authors
Akhmetov, Zhansen
Ruderman, Alex
Journal Title
Journal ISSN
Volume Title
Publisher
IET Power Electronics
Abstract
This study addresses the calculation of current total harmonic distortion (THD) for three-phase (3P) pulse-width modulation (PWM) inverters. First, it demonstrates how an analytical approach to PWM current ripple normalised mean square (NMS) calculation introduced in the late 1980s for a two-level (2L) inverter can be used for current THD evaluation. Second, it is shown how to evaluate current THD for a three-level (3L) 3P inverter using the current ripple NMS concept. Though considered is a 3P cascaded inverter with one H-bridge per phase, the results are applicable to popular 3L neutral point clamped (T-type) and flying capacitor inverters.
Description
Citation
Akhmetov, Z., & Ruderman, A. (2020). Analytical current THD evaluation for three‐phase voltage source inverters. IET Power Electronics, 13(6), 1286–1289. https://doi.org/10.1049/iet-pel.2019.1257
Collections
Endorsement
Review
Supplemented By
Referenced By
Creative Commons license
Except where otherwised noted, this item's license is described as Attribution-NonCommercial-ShareAlike 3.0 United States