Data Acquisition System for Microwave Kinetic Inductance Detectors

dc.contributor.authorBekbalanova, Marzhan
dc.contributor.authorShafiee, Mehdi
dc.contributor.authorKizheppatt, Vipin
dc.contributor.authorKazykenov, Zhaksylyk
dc.contributor.authorAlzhanov, Baurzhan
dc.contributor.authorSmoot, George F.
dc.contributor.authorGrossan, Bruce
dc.date.accessioned2019-12-11T08:51:46Z
dc.date.available2019-12-11T08:51:46Z
dc.date.issued2019
dc.descriptionhttps://iopscience.iop.org/article/10.1088/1742-6596/1182/1/012006en_US
dc.description.abstractEnergetic Cosmos Laboratory is developing Kinetic Inductance Detectors (MKID) for mm/submm astronomy purposes. In order to measure the instantaneous resonance frequency and dissipation of superconducting microresonators of the MKID arrays, we have developed a data acquisition system with emphasis on precision, readout speed and digital processing capabilities. We use IQ mixer to down convert the MKIDs signal in the range of 20-80 MHz, then digitize them by 250 MSPS ADC. Processed data at FPGA-Kintex 7 will be transferred to the PC for further analysis by the rate of 10 Gbit/sec. In this report, we describe the technical details and the algorithm we developed.en_US
dc.identifier.citationBeisenova, A., Issatayeva, A., Sovetov, S., Korganbayev, S., Jelbuldina, M., Ashikbayeva, Z., … Tosi, D. (2019). Multi-fiber distributed thermal profiling of minimally invasive thermal ablation with scattering-level multiplexing in MgO-doped fibers. Biomedical Optics Express, 10(3), 1282. https://doi.org/10.1364/boe.10.001282en_US
dc.identifier.other10.1088/1742-6596/1182/1/012006
dc.identifier.urihttp://nur.nu.edu.kz/handle/123456789/4375
dc.language.isoenen_US
dc.publisherIOP PUBLISHING LTDen_US
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.subjectMicrowave Kinetic Inductance Detectorsen_US
dc.subjectMKIDen_US
dc.subjectfrequency domain multiplexingen_US
dc.subjectFDMen_US
dc.titleData Acquisition System for Microwave Kinetic Inductance Detectorsen_US
dc.typeArticleen_US
workflow.import.sourcescience

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Data Acquisition System for Microwave Kinetic Inductance Detectors.pdf
Size:
778.02 KB
Format:
Adobe Portable Document Format
Description:
Article
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
6 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections