Application of Different Optimization Algorithms for Optimal Sizing of PV/Wind/Diesel/Battery Storage Stand-Alone Hybrid Microgrid

dc.contributor.authorDiab, Ahmed A. Zaki
dc.contributor.authorSultan, Hamdy M.
dc.contributor.authorMohamed, Ihab S.
dc.contributor.authorKuznetsov, Oleg
dc.contributor.authorTon, Duc Do
dc.date.accessioned2020-05-20T06:00:54Z
dc.date.available2020-05-20T06:00:54Z
dc.date.issued2019-08-21
dc.description.abstractIn this paper, a simulation model describing the operation of a PV/wind/diesel hybrid microgrid system with battery bank storage has been proposed. Optimal sizing of the proposed system has been presented to minimize the cost of energy (COE) supplied by the system while increasing the reliability and efficiency of the system presented by the loss of power supply probability (LPSP). Novel optimization algorithms of Whale Optimization Algorithm (WOA), Water Cycle Algorithm (WCA), Moth-Flame Optimizer (MFO), and Hybrid particle swarm-gravitational search algorithm (PSOGSA) have been applied for designing the optimized microgrid. Moreover, a comprehensive comparison has been accomplished between the proposed optimization techniques. The optimal sizing of the system components has been carried out using real-time meteorological data of Abu-Monqar village located in the Western Desert of Egypt for the first time for developing this promising remote area. Statistical study for determining the capability of the optimization algorithm in finding the optimal solution has been presented. Simulation results confirmed the promising performance of the hybrid WOA over the other algorithms.en_US
dc.identifier.citationDiab, A. A. Z., Sultan, H. M., Mohamed, I. S., Kuznetsov, O. N., & Do, T. D. (2019). Application of Different Optimization Algorithms for Optimal Sizing of PV/Wind/Diesel/Battery Storage Stand-Alone Hybrid Microgrid. IEEE Access, 7, 119223–119245. https://doi.org/10.1109/access.2019.2936656en_US
dc.identifier.issn2169-3536
dc.identifier.other10.1109/ACCESS.2019.2936656
dc.identifier.urihttps://ieeexplore.ieee.org/document/8808850
dc.identifier.urihttps://doi.org/10.1109/access.2019.2936656
dc.identifier.urihttp://nur.nu.edu.kz/handle/123456789/4746
dc.language.isoenen_US
dc.publisherIEEEen_US
dc.relation.ispartofseriesIEEE Access;Volume: 7
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.subjectoptimizationen_US
dc.subjectcost of energyen_US
dc.subjectCOEen_US
dc.subjectIsolated microgridsen_US
dc.subjectloss of power supply probabilityen_US
dc.subjectLPSPen_US
dc.subjectResearch Subject Categories::TECHNOLOGYen_US
dc.titleApplication of Different Optimization Algorithms for Optimal Sizing of PV/Wind/Diesel/Battery Storage Stand-Alone Hybrid Microgriden_US
dc.typeArticleen_US
workflow.import.sourcescience

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Application of Different Optimization Algorithms for Optimal Sizing of PV Wind Diesel Battery Storage Stand-Alone Hybrid Microgrid.pdf
Size:
2.8 MB
Format:
Adobe Portable Document Format
Description:
Article

Collections