Automated segmentation of optic nerve head for the topological assessment

dc.contributor.authorKo, M. W.L.
dc.contributor.authorLeung, C. K.S.
dc.contributor.authorYuen, T. Y.P.
dc.contributor.institutionService Division for Contractors
dc.date.accessioned2025-12-17T20:31:45Z
dc.date.issued2016-07-05
dc.descriptionPublisher Copyright: © 2016 IEEE.
dc.description.abstractAn automated method is proposed to detect the optic nerve head (ONH) surface profile for the three-dimensional reconstruction of the ONH surface topology and for the determination of the optic nerve head surface depth (ONHSD) and optic nerve head surface volume (ONHSV). The proposed automated method was evaluated in 15 optic disc center B-scans and was compared to the manual detection method. The results showed a good agreement between the measurement of ONHSD (0.7% ± 1.0%) and ONHSV (-1.4% ± 3.2%) using manual and automated ONH profile, respectively.en
dc.format.extent225440
dc.identifier.citationKo, M W L, Leung, C K S & Yuen, T Y P 2016, Automated segmentation of optic nerve head for the topological assessment. in 2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges, GMEPE/PAHCE 2016., 7504611, 2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges, GMEPE/PAHCE 2016, Institute of Electrical and Electronics Engineers Inc., 2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges, GMEPE/PAHCE 2016, Madrid, Spain, 4/4/16. https://doi.org/10.1109/GMEPE-PAHCE.2016.7504611
dc.identifier.citationother
dc.identifier.doi10.1109/GMEPE-PAHCE.2016.7504611
dc.identifier.isbn9781509024858
dc.identifier.otherQABO: 84979993797
dc.identifier.urihttps://nur.nu.edu.kz/handle/123456789/17573
dc.identifier.urlhttps://www.scopus.com/pages/publications/84979993797
dc.identifier.urlhttps://www.scopus.com/pages/publications/84979993797#tab=citedBy
dc.language.isoeng
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.relation.ispartof2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges, GMEPE/PAHCE 2016
dc.relation.ispartofseries2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges, GMEPE/PAHCE 2016
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectoptic nerve head
dc.subjectoptical coherence tomography (OCT)
dc.subjectsegmentation
dc.subjecttopology
dc.subjectComputer Networks and Communications
dc.subjectBiomedical Engineering
dc.subjectRadiology Nuclear Medicine and imaging
dc.subjectHealth Informatics
dc.subjectInstrumentation
dc.titleAutomated segmentation of optic nerve head for the topological assessmenten
dc.type/dk/atira/pure/researchoutput/researchoutputtypes/contributiontobookanthology/conference

Files