About voltage total harmonic distortion for single- and three-phase multilevel inverters [Article]

dc.contributor.authorRuderman, Alexander
dc.date.accessioned2019-08-29T04:11:06Z
dc.date.available2019-08-29T04:11:06Z
dc.date.issued2015-03
dc.descriptionhttps://ieeexplore.ieee.org/document/6862003en_US
dc.description.abstractMany recent multilevel inverter papers end up with voltage total harmonic distortion (THD) values obtained from numerical voltage spectrum calculations (measurements). Motivated by IEEE Standard 519, a part of the multilevel research community uses a limited harmonic count to evaluate the multilevel voltage quality. First, this causes significant voltage THD underestimation, particularly for relatively high frequency PWM. Second, for a three-phase star-connected balanced load with an isolated neutral and phase symmetric modulation strategy, the calculated load line and phase voltage THD become different. However, simple considerations show that line and phase voltage THDs are essentially the same in this case. It may be difficult to judge about the multilevel voltage quality given a numerically calculated (measured) voltage THD value that may be subject to computation errors. Presented are simple smooth hyperbolic voltage THD upper and lower bound approximations for single- and three-phase inverters with nearest synchronous switching. They are valid for arbitrary modulation indices and uniformly distributed level counts and may practically serve as good reference values.en_US
dc.identifier.citationRuderman, A. (2015). About Voltage Total Harmonic Distortion for Single- and Three-Phase Multilevel Inverters. IEEE Transactions on Industrial Electronics, 62(3), 1548–1551. https://doi.org/10.1109/tie.2014.2341557en_US
dc.identifier.issn1548–1551
dc.identifier.urihttp://nur.nu.edu.kz/handle/123456789/4161
dc.language.isoenen_US
dc.publisherNazarbayev University School of Engineering and Digital Sciencesen_US
dc.rightsAttribution-NonCommercial-ShareAlike 3.0 United States*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/us/*
dc.subjectDC–AC power conversionen_US
dc.subjectmultilevel invertersen_US
dc.subjectpulsewidth-modulated power convertersen_US
dc.subjectvoltage total harmonic distortion (THD)en_US
dc.titleAbout voltage total harmonic distortion for single- and three-phase multilevel inverters [Article]en_US
dc.typeArticleen_US
workflow.import.sourcescience

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
About voltage total harmonic distortion for single- and three-phase multilevel inverters.pdf
Size:
622.55 KB
Format:
Adobe Portable Document Format
Description:
Article

Collections