Publisher Correction: Label-free fiber-optic spherical tip biosensor to enable picomolar-level detection of CD44 protein
| dc.contributor.author | Aliya Bekmurzayeva | |
| dc.contributor.author | Zhannat Ashikbayeva | |
| dc.contributor.author | Zhuldyz Myrkhiyeva | |
| dc.contributor.author | Aigerim Nugmanova | |
| dc.contributor.author | Madina Shaimerdenova | |
| dc.contributor.author | Takhmina Ayupova | |
| dc.contributor.author | Daniele Tosi | |
| dc.date.accessioned | 2025-08-21T04:37:41Z | |
| dc.date.available | 2025-08-21T04:37:41Z | |
| dc.date.issued | 2021-11-11 | |
| dc.description.abstract | The original article contained a duplicated Figure 4 legend. The text "The experimental setup used for the CD44 protein measurements using a fiber optic spherical tip-based biosensor. Surface functionalization steps are shown in the zoomed area. APTMS 3-(aminopropyl)trimethoxysilane, MUA 11-mercaptoundecanoic acid, EDC 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride, NHS N-hydroxysuccinimide, OBR optical backscatter reflectometry." now reads: "Studying specificity of functionalized fiber optic tip biosensor for CD44 protein detection by measuring control proteins (IL-4 and thrombin). The reference protein concentration used was 6 pM. (a) Amplitude change of the sensors when measuring target protein vs. control proteins in different concentrations; (b) Response of the sensors normalized to their respective RI sensitivities." | en |
| dc.identifier.citation | Bekmurzayeva Aliya, Ashikbayeva Zhannat, Myrkhiyeva Zhuldyz, Nugmanova Aigerim, Shaimerdenova Madina, Ayupova Takhmina, Tosi Daniele. (2021). Publisher Correction: Label-free fiber-optic spherical tip biosensor to enable picomolar-level detection of CD44 protein. Scientific Reports. https://doi.org/10.1038/s41598-021-00914-2 | en |
| dc.identifier.doi | 10.1038/s41598-021-00914-2 | |
| dc.identifier.uri | https://doi.org/10.1038/s41598-021-00914-2 | |
| dc.identifier.uri | https://nur.nu.edu.kz/handle/123456789/9711 | |
| dc.language.iso | en | |
| dc.publisher | Springer Science and Business Media LLC | |
| dc.relation.ispartof | Scientific Reports | en |
| dc.rights | All rights reserved | en |
| dc.source | Scientific Reports, 11(1), 19583, (2021) | en |
| dc.subject | Biosensor | en |
| dc.subject | Protein detection | en |
| dc.subject | Nanotechnology | en |
| dc.subject | Materials science | en |
| dc.subject | type of access: open access | en |
| dc.title | Publisher Correction: Label-free fiber-optic spherical tip biosensor to enable picomolar-level detection of CD44 protein | en |
| dc.type | Erratum | en |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Publisher Correction Label-free fiber-optic spherical tip biosensor to enable picomolar-level detection of CD44 protein.pdf
- Size:
- 663.42 KB
- Format:
- Adobe Portable Document Format