DSpace Repository

POWER SYSTEM STABILITY IMPROVEMENT CONSIDERING DRIVE TRAIN OSCILLATIONS OF VIRTUAL SYNCHRONOUS GENERATOR-REGULATED TYPE-4 WIND TURBINES

Система будет остановлена для регулярного обслуживания. Пожалуйста, сохраните рабочие данные и выйдите из системы.

Show simple item record

dc.contributor.author Yazdi, Seyed Saeied Heidari
dc.contributor.author Shokri-Kalandaragh, Yaser
dc.contributor.author Bagheri, Mehdi
dc.date.accessioned 2022-11-17T04:06:04Z
dc.date.available 2022-11-17T04:06:04Z
dc.date.issued 2022
dc.identifier.citation Yazdi, S. S. H., Shokri‐Kalandaragh, Y., & Bagheri, M. (2022). Power system stability improvement considering drive train oscillations of virtual synchronous generator‐regulated type‐4 wind turbines. IET Renewable Power Generation. https://doi.org/10.1049/rpg2.12616 en_US
dc.identifier.uri http://nur.nu.edu.kz/handle/123456789/6803
dc.description.abstract The type-4 wind turbine generators (WTGs) can provide inertial frequency response by implementing the virtual synchronous generator (VSG) concept. However, unstable torsional oscillations (TOs) would be induced in the multi-mass-spring drive-train which can destabilize the entire power system. In this study, participation factor analyses are performed for a power system inclusive of a thermal unit and aggregated WTG system. The system’s eigenvalues are characterized and the possible detrimental impacts of TOs on the inertia provision process and overall power system stability are demonstrated and the related stability limits are identified. A comprehensive active torsional oscillations damper (CA-TOD) and a supercapacitor-based energy storage system (ESS) are presented and discussed to implement the CA-TOD. A state of charge (SoC) regulator is also employed to set the reference speed difference for the turbine-generator. Small-signal studies and electro-magnetic transient (EMT) simulations are performed to evaluate the functionality of the CA-TOD and SoC controller and estimate their impacts on the system’s dynamics. The robust performance of the CA-TOD is compared to the band-pass filter-based TOD by sweeping key control parameters of the VSG and emulating drive-train parameter uncertainty. Key results are cross-verified by EMT simulations of a multimachine power system. en_US
dc.language.iso en en_US
dc.publisher IET Renewable Power Generation en_US
dc.rights Attribution-NonCommercial-ShareAlike 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-sa/3.0/us/ *
dc.subject Type of access: Open Access en_US
dc.subject wind turbines en_US
dc.subject Power system en_US
dc.title POWER SYSTEM STABILITY IMPROVEMENT CONSIDERING DRIVE TRAIN OSCILLATIONS OF VIRTUAL SYNCHRONOUS GENERATOR-REGULATED TYPE-4 WIND TURBINES en_US