DSpace Repository

Photocatalytic Treatment of a Synthetic Wastewater

Система будет остановлена для регулярного обслуживания. Пожалуйста, сохраните рабочие данные и выйдите из системы.

Show simple item record

dc.contributor.author Yerkinova, Azat
dc.contributor.author Balbayeva, Gaukhar
dc.contributor.author Inglezakis, Vassilis J.
dc.contributor.author Poulopoulos, Stavros G.
dc.date.accessioned 2020-05-19T10:43:47Z
dc.date.available 2020-05-19T10:43:47Z
dc.date.issued 2018-01
dc.identifier.citation Yerkinova, A., Balbayeva, G., Inglezakis, V. J., & Poulopoulos, S. G. (2018). Photocatalytic Treatment of a Synthetic Wastewater. IOP Conference Series: Materials Science and Engineering, 301, 12143. https://doi.org/10.1088/1757-899x/301/1/012143 en_US
dc.identifier.issn 10.1088/1757-899x/301/1/012143
dc.identifier.other 10.1088/1757-899x/301/1/01214
dc.identifier.uri https://iopscience.iop.org/article/10.1088/1757-899X/301/1/012143
dc.identifier.uri https://doi.org/10.1088/1757-899x/301/1/012143
dc.identifier.uri http://nur.nu.edu.kz/handle/123456789/4733
dc.description.abstract This work aimed at investigating the photocatalytic treatment of a synthetic wastewater using UV light (254 nm, 6 W), TiO2 catalyst and H2O2 in a batch recycle annular photoreactor. The total volume of the solution was 250 mL while the irradiated volume in the annular photoreactor with 55.8 mL. Each experiment lasted 120 min and samples were sent for Total Carbon and HPLC analysis. The stock wastewater had initial total carbon 1118 mg L-1. The effect of the presence of phenol in the wastewater on total carbon (TC) removal was also studied. It was shown that the photocatalytic treatment was effective only when initial TC was decreased to 32 mg L-1, whereas the optimum TiO2 concentration was 0.5 g L-1, leading to a TC removal up to 56%. For the same initial carbon load, the optimum H2O2 concentration was found to be 67 mg L-1 resulting in 55% TC removal. Combining, however, TiO2 and H2O2 did not lead to better performance, as 51% TC removal was observed. In contrast, when initial carbon in the wastewater was partially substituted by phenol, the combination of catalyst and hydrogen peroxide was beneficial. Specifically, when 10 ppm of phenol were added keeping the same initial TC concentration, UV/TiO2 treatment resulted in 46% TC removal and 98% phenol conversion, whereas using additionally H2O2 led to 100% phenol conversion after 45 minutes and 81% TC removal. en_US
dc.language.iso en en_US
dc.publisher IOP Publishing en_US
dc.relation.ispartofseries IOP Conference Series: Materials Science and Engineering;
dc.rights Attribution-NonCommercial-ShareAlike 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-sa/3.0/us/ *
dc.subject Photocatalytic Treatment en_US
dc.subject Synthetic Wastewater en_US
dc.subject Advanced Oxidation Processes en_US
dc.subject AOP en_US
dc.subject Research Subject Categories::TECHNOLOGY en_US
dc.subject hazardous compounds en_US
dc.title Photocatalytic Treatment of a Synthetic Wastewater en_US
dc.type Article en_US
workflow.import.source science


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-ShareAlike 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 3.0 United States