DSpace Repository

Rapid liquid chromatography–tandem mass spectrometry method for the determination of a broad mixture of pharmaceuticals in surface water

Show simple item record

dc.contributor.author Conley, Justin
dc.contributor.author Symes, Steven
dc.contributor.author Kindelberger, Scott
dc.contributor.author Richards, Sean
dc.date.accessioned 2016-11-21T05:51:12Z
dc.date.available 2016-11-21T05:51:12Z
dc.date.issued 2008
dc.identifier.uri http://nur.nu.edu.kz/handle/123456789/1901
dc.description.abstract Herein, a new method for the detection of 13 different pharmaceuticals and one metabolite in surface water at low ng/L levels is described. The method utilizes ultra performance liquid chromatography–tandem mass spectrometry and a solid-phase extraction sample preparation. Mean method detection limits were low (4.10 ng/L) and overall solid-phase extraction recovery and reproducibility was adequate (mean recovery, 77.9%; mean RSD, 7.3%). The method allows for quick run times and minimal solvent use as compared with other previously reported high performance liquid chromatography-based methods. Application of this method for the detection of pharmaceuticals in Tennessee River surfacewater determined that caffeine, sulfamethoxazole, and carbamazepine were frequently detected (100% of samples). Trimethoprim was moderately detected (30% of samples); acetaminophen, atorvastatin, and lovastatin were infrequently detected (10% of samples); and ciprofloxacin, diltiazem, fluoxetine, levofloxacin, norfluoxetine, ranitidine, and sertraline were not detected. This study reports the first detection of lovastatin in surface water. ru_RU
dc.language.iso en ru_RU
dc.publisher Journal of Chromatography A. www.sciencedirect.com ru_RU
dc.rights Attribution-NonCommercial-ShareAlike 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-sa/3.0/us/ *
dc.subject ultra performance liquid chromatography ru_RU
dc.subject solid-phase extraction ru_RU
dc.subject tandem mass spectrometry ru_RU
dc.subject environmental analysis ru_RU
dc.subject surface water ru_RU
dc.subject pharmaceutical ru_RU
dc.title Rapid liquid chromatography–tandem mass spectrometry method for the determination of a broad mixture of pharmaceuticals in surface water ru_RU
dc.type Article ru_RU


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-ShareAlike 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 3.0 United States

Video Guide

Submission guideSubmission guide

Submit your materials for publication to

NU Repository Drive

Browse

My Account

Statistics