Tooth enamel EPR dosimetry: optimization of EPR spectra recording parameters and effect of sample mass on spectral sensitivity

Show simple item record

dc.contributor.author Zhumadilov, Kassym
dc.contributor.author Ivannikov, Alexander
dc.contributor.author Skvortsov, Valeriy
dc.contributor.author Stepanenko, Valeriy
dc.contributor.author Zhumadilov, Zhaxybay
dc.contributor.author Endo, Satoru
dc.contributor.author Tanaka, Kenichi
dc.contributor.author Hoshi, Masaharu
dc.date.accessioned 2016-02-19T04:42:24Z
dc.date.available 2016-02-19T04:42:24Z
dc.date.issued 2005
dc.identifier.uri http://nur.nu.edu.kz/handle/123456789/1290
dc.description.abstract conditions were optimized. The uncertainty of dose determination was obtained as the mean square deviation of doses, determined with the use of a spectra deconvolution program, from the nominal doses for ten enamel samples irradiated in the range from 0 to 500 mGy. The spectra were recorded at different microwave powers and accumulation times. It was shown that minimal uncertainty is achieved at the microwave power of about 2 mW for a used spectrometer JEOL JES-FA100. It was found that a limit of the accumulation time exists beyond which uncertainty reduction is ineffective. At an established total time of measurement, reduced uncertainty is obtained by averaging the experimental doses determined from recorded spectra following intermittent sample shaking and sample tube rotation, rather than from one spectrum recorded at longer accumulation time. The effect of sample mass on the spectrometer’s sensitivity was investigated in order to find out how to make appropriate corrections. ru_RU
dc.language.iso en ru_RU
dc.publisher Journal of Radiation Research. http://jrr.jstage.jst.go.jp ru_RU
dc.rights Attribution-NonCommercial-ShareAlike 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-sa/3.0/us/ *
dc.subject EPR spectroscopy ru_RU
dc.subject tooth enamel ru_RU
dc.subject dose determination ru_RU
dc.subject Research Subject Categories::MEDICINE ru_RU
dc.title Tooth enamel EPR dosimetry: optimization of EPR spectra recording parameters and effect of sample mass on spectral sensitivity ru_RU
dc.type Article ru_RU


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-ShareAlike 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-ShareAlike 3.0 United States