Retrofitting of Full-Scale Confined Masonry Building Using Ferro-Cement Overlay

dc.contributor.authorShazim Ali Memon
dc.contributor.authorBora Gencturk
dc.contributor.authorKhan Shahzada
dc.contributor.authorSyed Mustafa Ali Shah
dc.date.accessioned2025-10-31T11:52:18Z
dc.date.issued2017-10-01 00:00:00
dc.description.abstractIn this paper, the performance of a full-scale single-story confined masonry building was investigated by subjecting it to quasi-static cyclic loading. The configuration and materials used for the test specimen were typical of those found in the northern areas of Pakistan as well as in the surrounding regions. The retrofitting of the building was done using ferro-cement overlay and cement-based grout injection. Damage mechanism and force-deformation behavior of the retrofitted structure are compared with those of the original structure to quantify the beneficial effects of the retrofitting. It was found that the lateral stiffness, lateral load, and deformation capacity of the retrofitted building were improved, whereas the ductility decreased slightly. The damage mechanism was transformed from mixed compression-flexural-shear to a more stable flexural-rocking mode. The results from this paper are expected to guide future research efforts on developing design recommendations for, and vulnerability assessment of, similar buildings around the world.
dc.identifier.doi10.1061/(ASCE)CF.1943-5509.0001060
dc.identifier.urihttps://nur.nu.edu.kz/handle/123456789/12147
dc.languageen
dc.publisherhttps://doi.org/10.1061/(ASCE)CF.1943-5509.0001060
dc.rightsAll rights reserved
dc.sourceJournal of Performance of Constructed Facilities
dc.subjectProgramming language
dc.subjectCreep
dc.subjectComputer science
dc.subjectComposite material
dc.subjectEngineering
dc.subjectMaterials science
dc.subjectDeformation (meteorology)
dc.subjectUnreinforced masonry building
dc.subjectFull scale
dc.subjectStiffness
dc.subjectGeotechnical engineering
dc.subjectDuctility (Earth science)
dc.subjectGrout
dc.subjectCement
dc.subjectOverlay
dc.subjectFlexural strength
dc.subjectStructural engineering
dc.subjectMasonry
dc.subjectRetrofitting
dc.titleRetrofitting of Full-Scale Confined Masonry Building Using Ferro-Cement Overlay
dc.typeArticle

Files